Search results for "Capillary action"
showing 10 items of 179 documents
Estimating the macroscopic capillary length from Beerkan infiltration experiments and its impact on saturated soil hydraulic conductivity predictions
2020
International audience; The macroscopic capillary length, λc, is a fundamental soil parameter expressing the relative importance of the capillary over gravity forces during water movement in unsaturated soil. In this investigation, we propose a simple field method for estimating λc using only a single-ring infiltration experiment of the Beerkan type and measurements of initial and saturated soil water contents. We assumed that the intercept of the linear regression fitted to the steady-state portion of the experimental infiltration curve could be used as a reliable predictor of λc. This hypothesis was validated by assessing the proposed calculation approach using both analytical and field d…
Determination of meropenem in endotracheal tubes by in-tube solid phase microextraction coupled to capillary liquid chromatography with diode array d…
2017
Meropenem is a widely used antimicrobial for the treatment of infections associated with the use of invasive medical devices in intensive care unit patients. These treatments are not always effective, in fact, in-vitro studies have demonstrated the difficulty of antimicrobials to penetrate into the biofilm, however in-vivo studies of the effect of these compounds is a trend, mostly because of the complexity of pulmonary samples extracted from ETTs. Therefore, the objective of this study was to evaluate in-tube solid phase microextraction (in-tube SPME) coupled to capillary liquid chromatography (CapLC) with DAD to determine meropenem in Errs in order to estimate the penetration capability i…
Self-packed core shell nano liquid chromatography columns and silica-based monolithic trap columns for targeted proteomics.
2016
Self-preparation of nano liquid chromatography (nLC) columns has advantages regarding cost and flexibility. For targeted proteomics, we evaluated several approaches for particle-packing nLC columns and manufacturing fritless silica-based monolithic trap columns (50μm inner diameter). Our preferred approach for nLC column preparation was to magnetically stir Accucore core shell particles (C18 stationary phase) in ACN/water (80/20, v/v) suspensions during pressure-driven filling of polymer-fritted standard fused silica capillaries. The columns were ready for use about one hour after preparation had begun. They had comparable peak capacities (peptides) to commercial columns, and satisfactory w…
An Introduction to Soil and Water Infiltration
2016
This chapter provides a short presentation of general characteristics of the soil. Basic concepts concerning soil water content and potential and flow of water in the porous medium are then reported since these concepts are diffusely used throughout this book. The infiltration process is finally illustrated considering different modeling approaches. In particular, development of analytical infiltration models is described with reference to one-dimensional gravity-free water absorption, one-dimensional gravity driven infiltration, one-dimensional gravity and capillary driven infiltration and, finally, three-dimensional gravity and capillary driven infiltration.
Study of water adsorption and capillary bridge formation for SiO(2) nanoparticle layers by means of a combined in situ FT-IR reflection spectroscopy …
2014
Water adsorption and capillary bridge formation within a layer of SiO2-nanoparticles were studied in situ by means of a combination of quartz crystal microbalance (QCM-D) with dissipation analysis and Fourier transformation infrared reflection absorption spectroscopy (FT-IRRAS). FT-IR data were employed to distinguish the “ice-like” and “liquid-like” contributions and to support the analysis of the QCM-D data concerning mass change and dissipation. Combined measurements show that for SiO2-nanoparticles with a diameter of about 250 nm, the formation of two adsorbed monolayers of water as well as bulk water leads to a rather linear increase in the dissipation for relative humidity values of u…
A capillary liquid chromatography method for benzalkonium chloride determination as a component or contaminant in mixtures of biocides
2015
A method for quantifying benzalkonium chloride (BAK), an alkyl dimethyl benzyl ammonium compound, in several biocides formulations is proposed. A tertiary amine like N-(3-aminopropyl)-N-dodecyl-1,3-propanediamine (TA) and a straight-chain alkyl ammonium compound like trimethyl-tetradecyl ammonium chloride (TMTDAC), have been employed as trade surfactants besides BAK. Two capillary analytical columns with different polarities are tested: inertsil CN-3 capillary column (150mm×0.5mm i.d., 3μm particle diameter) and a non endcapped Zorbax C18 capillary column (35mm×0.5mm i.d., 5μm particle diameter). This latter column provided the best separation of the BAK homologues in less than 12min using …
Comparative column chromatographic estimations of phenylalanine in plasma, whole blood, native and paper-dried capillary blood of healthy children an…
1984
The concentration of phenylalanine in plasma, whole venous and capillary blood, and paper-dried blood of 75 probands (25 healthy adults, 27 healthy children, and 23 patients with hyperphenylalaninaemia) were measured by use of a sensitive short column chromatography method. The comparison of the values in each group of probands by several statistic methods showed an excellent correlation of the phenylalanine concentration in paper-dried whole blood to those measured in venous plasma. Evaluation of the analytical method revealed a high sensitivity and accuracy by use of a sample volume of 50 microliter. We would therefore suggest that the estimation of phenylalanine for the diagnosis and the…
The effect of cigar smoking on the lingual microcirculation
2005
The aim of this study was to analyze the lingual microcirculation in vivo and to evaluate the effects on it of cigar smoking, using computerized videocapillaroscopy. Twenty-five healthy nonsmokers and 25 healthy smokers were examined. For each subject we evaluated the visibility, course, tortuosity, and any images characteristic of capillary loops, as well as the possible presence of microhemorrhages, the average caliber of the capillary loops, and the number of capillary loops visible per square millimeter. The investigation of the lingual mucosa revealed capillary loops with a course parallel to the surface. In smokers, capillary loops had a smaller caliber (P < 0.001) and there was a hig…
Longitudinal analysis of taurine induced effects on the tear proteome of contact lens wearers and dry eye patients using a RP-RP-Capillary-HPLC-MALDI…
2012
Tear proteomic studies revealed distinct similarities between contact lens wearers and dry eye patients. AMO Complete® multipurpose contact lens cleaning solutions containing taurine seem to have a beneficial effect regarding contact lens induced dry eye. To illuminate the effect of taurine on the tear proteome of contact lens wearers and sicca patients we developed a gel-based RP-RP capillary HPLC-MALDI TOF/TOF MS strategy. Two contact lens wearer groups, one using eye drops containing 0.05% taurine; the other for control physiological NaCl solution were monitored. Also, a third group of sicca patients using taurine solution was studied (N=4 individuals/group). Tear pools of each group at …
Liquid gas techniques for GC trace analysis
1990
Liquid gases (LG), i.e. low boiling compounds with vapor pressures below 5 bar at room temperature, are introduced as solvents for trace analyses. A system for preparin, diluting and handling LG solutions safely and conveniently in 5 to 500 μl amounts was developed as well as a syringe for direct injection of μl-LG samples into capillary GC. Even technical grade LG are of high purity. GC/FID of LG solutions (starting at −60°C) allows the separation of volatile traces from the solvent peak: e.g., dichloromethane can be measured in the picogram range.